Immediate Treatment
:
• Disconnect power supply first for safety
• Dry the connector (compressed air blow-drying / low-temperature baking)
Seal Check
:
• Inspect O-ring for damage or aging
• Replace damaged sealing parts promptly
Torque Control
:
• Verify installation torque to avoid seal damage from over-tightening
Protection Upgrade
:
• Upgrade to IP68 pre-cast molded models for outdoor/underwater scenarios
• Ensure long-term waterproof performance in harsh wet environments
Technical Note: Timely handling of water ingress and compliance with installation torque norms can prevent short circuits and corrosion. For outdoor/underwater applications, IP68 pre-cast molded connectors are recommended to fundamentally improve waterproof reliability.