Confirm application

What is the correspondence between the number of cores and the rated current of the M9 connector, and how can it be used to match the power of the equipment?

Core Count & Rated Current Correlation of M9 Connectors & Equipment Power Matching

Core Count - Rated Current Correlation Table (DC 30V)

Core Count Rated Current per Core Applicable Scenario
2/3 cores 5A High-current small-channel transmission
4/5 cores 3A Medium-current multi-channel transmission
6/8 cores 2A Low-current multi-channel signal transmission

Equipment Power Matching Method

Matching Formula

Total Power ≤ Rated Voltage × Rated Current per Core × Effective Core Count (reserve 20% margin)
Note : All values are rated under DC 30V.

Application Limitation

Only suitable for signal transmission and low-power power supply scenarios, not applicable for high-power load connection to avoid overcurrent damage.

Technical Note: The rated current of M9 connectors decreases with the increase of core count due to space limitation; the 20% margin is reserved to avoid connector overheating caused by instantaneous current surge in actual use.